Just Accepted Manuscripts
Articles

An optimised computational fluid dynamic approach for the energy performance analysis of ventilated façades

Sofia Pastori
Politecnico di Milano
Giacomo Scrinzi
Politecnico di Milano
Enrico Sergio Mazzucchelli
Politecnico di Milano
Angelo Lucchini
Politecnico di Milano

Published 2025-12-05

Keywords

  • Ventilated façade,
  • CFD,
  • Energy efficiency,
  • Timber-concrete composite façade,
  • Building monitoring

Abstract

The paper deals with the use of Computational Fluid Dynamics (CFD) for the thermal performance analysis and optimisation of prefabricated Timber-Concrete Composite (TCC) ventilated façades. TCC envelopes are composed of an internal insulated timber-frame wall coupled to an external concrete slab, separated by a ventilated air cavity. Such systems join the properties of engineered timber (good seismic behaviour, low thermal conductivity, environmental sustainability, and ease of system integration) with those of concrete (high thermal inertia, excellent durability and fire resistance). There is very limited knowledge on the performance of TCC facades, especially for what concerns their thermal behaviour. For this reason, a TCC ventilated façade located in the north of Italy was monitored over one year, and the results collected were used to calibrate and validate a CFD model. A new solver algorithm was developed to speed up the CFD simulations, allowing up to 45 times faster analysis compared to conventional solvers. Thanks to this improvement, the final model is suitable to be used for time-efficient thermal analysis (a full-day real-time simulation takes approximately 23 minutes), limiting the expensive and time-consuming construction of mock-ups. The CFD model developed is suitable for the thermal performance analysis and optimisation of TCC ventilated facades, but also for generic ventilated facades with external massive cladding, both in the case of new and existing buildings.

References

  1. [1] Asdrubali F, Ferracuti B, Lombardi L et al (2017) A Review of Structural, Thermo-Physical, Acoustical, and Environmental Properties of Wooden Materials for Building Applications. Building and Environment 114:307–332.
  2. [2] Janssen H (2018) Characterization of Hygrothermal Properties of Wood-Based Products—Impact of Moisture Content and Temperature. Constr. Build. Mater 185:39–43.
  3. [3] Fortuna S, Mora TD, Peron F, Romagnoni P (2017) Environmental Performances of a Timber-Concrete Prefabricated Composite Wall System. Energy Procedia 113:90–97.
  4. [4] Pastori S, Mereu R, Mazzucchelli ES et al (2021) Energy Performance Evaluation of a Ventilated Façade System through Cfd Modeling and Comparison with International Standards. Energies 14:193. doi:10.3390/en14010193.
  5. [5] Destro R, Boscato G, Mazzali U et al (2015) Structural and Thermal Behaviour of a Timber-Concrete Prefabricated Composite Wall System. Energy Procedia 78:2730–2735.
  6. [6] Patania F, Gagliano A, Nocera F et al (2010) Thermofluid-Dynamic Analysis of Ventilated Facades. Energy Build. 42:1148–1155. doi:10.1016/j.enbuild.2010.02.006.
  7. [7] Giancola E, Sanjuan C, Blanco E, Heras MR (2012) Experimental Assessment and Modelling of the Performance of an Open Joint Ventilated Façade during Actual Operating Conditions in Mediterranean Climate. Energy Build. 54:363–375. doi:10.1016/j.enbuild.2012.07.035.
  8. [8] Ciampi M, Leccese F, Tuoni G (2003) Ventilated Facades Energy Performance in Summer Cooling of Buildings. Sol. Energy 75:491–502. doi:10.1016/j.solener.2003.09.010.
  9. [9] Giancola E, Sánchez MN, Friedrich M et al (2018) Possibilities and Challenges of Different Experimental Techniques for Airflow Characterisation in the Air Cavities of Façades. J. Facade Des. Eng. 6:34–48. doi:10.7480/jfde.2018.3.2470.
  10. [10] Gagliano A, Nocera F, Aneli S (2016) Thermodynamic Analysis of Ventilated Façades under Different Wind Conditions in Summer Period. Energy Build. 122:131–139. doi:10.1016/j.enbuild.2016.04.035.
  11. [11] Jensen J, Bartak M, Drkal F (2007) Modeling and Simulation of a Double-Skin Facade System. In ASHRAE Transactions; Symposia, HI-02-21-3.
  12. [12] Manz H (2003) Numerical Simulation of Heat Transfer by Natural Convection in Cavities of Facade Elements. Energy Build. 35:305–311. doi:10.1016/S0378-7788(02)00088-9.
  13. [13] Xamán J, Álvarez G, Lira L, Estrada C (2005) Numerical Study of Heat Transfer by Laminar and Turbulent Natural Convection in Tall Cavities of Façade Elements. Energy Build. 37:787–794. doi:10.1016/j.enbuild.2004.11.001.
  14. [14] Pappas A, Zhai Z (2008) Numerical Investigation on Thermal Performance and Correlations of Double Skin Façade with Buoyancy-Driven Airflow. Energy Build. 40:466–475. doi:10.1016/j.enbuild.2007.04.002.
  15. [15] Safer N, Woloszyn M, Roux JJ (2005) Three-Dimensional Simulation with a CFD Tool of the Airflow Phenomena in Single Floor Double-Skin Facade Equipped with a Venetian Blind. Sol. Energy 79:193–203.
  16. [16] Sanjuan C, Suárez MJ, González M et al (2011) Energy Performance of an Open-Joint Ventilated Façade Compared with a Conventional Sealed Cavity Façade. Sol. Energy 85:1851–1863. doi:10.1016/j.solener.2011.04.028.
  17. [17] Baldinelli G (2009) Double Skin Façades for Warm Climate Regions: Analysis of a Solution with an Integrated Movable Shading System. Build. Environ. 44:1107–1118. doi:10.1016/j.buildenv.2008.08.005.
  18. [18] Stazi F, Ulpiani G, Pergolini M et al (2018) Experimental Comparison Between Three Types of Opaque Ventilated Facades. Open Constr. Build. Technol. J. 12:296–308. doi:10.2174/1874836801812010296.
  19. [19] Pastori S (2024) Timber-Concrete Composite Ventilated Envelope Systems. Experimental and Numerical Investigations for Thermal Performance Control and Optimization. Ph.D. Thesis, Politecnico di Milano, Milan, Italy, 2024.
  20. [20] OpenFOAM® v2206. https://www.openfoam.com/. Accessed 28 Oct 2025
  21. [21] EN ISO 6946:2017 Components and Building Elements—Thermal Resistance and Thermal Transmittance—Calculation Methods.
  22. [22] Tahmasebinia F, Lin L, Wu S et al (2023) Exploring the Benefits and Limitations of Digital Twin Technology in Building Energy. Appl. Sci. 13:8814.