Vol. 123, No. 1 (Supplement) 2018
Supplement abstract

3D virtual morphometry of human myometrium and uterine fibroids performed by Synchrotron Radiation- based Microtomography

Pasquapina Ciarmela
Università Politecnica delle Marche, Dipartimento Medicina Sperimentale e Clinica, Ancona
Stefania Greco
Università Politecnica delle Marche, Dipartimento Medicina Sperimentale e Clinica, Ancona
Giuliana Tromba
Elettra, Sincrotrone Trieste S.C.p.A., Trieste
Serena Pacilè
Elettra, Sincrotrone Trieste S.C.p.A., Trieste
Alessandro Zannotti
Università Politecnica delle Marche, Dipartimento Medicina Sperimentale e Clinica, Ancona
Giovanni Delli Carpini
Università Politecnica delle Marche, Dipartimento di Scienze Cliniche, Ancona
Stefano Raffaele Giannubilo
Università Politecnica delle Marche, Dipartimento di Scienze Cliniche, Ancona
Andrea Ciavattini
Università Politecnica delle Marche, Dipartimento di Scienze Cliniche, Ancona
Alessandra Giuliani
Università Politecnica delle Marche, Dipartimento di Scienze Cliniche, Ancona

Published 2018-12-30

Keywords

  • Myometrium,
  • leiomyoma,
  • morphometry,
  • microtomography,
  • synchrotron radiation

How to Cite

Ciarmela, P., Greco, S., Tromba, G., Pacilè, S., Zannotti, A., Delli Carpini, G., Giannubilo, S. R., Ciavattini, A., & Giuliani, A. (2018). 3D virtual morphometry of human myometrium and uterine fibroids performed by Synchrotron Radiation- based Microtomography. Italian Journal of Anatomy and Embryology, 123(1), 65. https://doi.org/10.13128/ijae-11364

Abstract

Uterine leiomyomas, or fibroids, are the most common gynecological tumors originating inside the myometrium. Leiomyomas bulk is caused by a disorder of fibrosis, characterized by production of large amount extracellular matrix (ECM) and by its disruption (1-3).

The ECM can be easily detected by histochemical methods. However, conventional micros- copy techniques are limited to two-dimensional images hampering the quantitative analysis or requiring digital 3D reconstruction of serial stained sections.

The impact of the microtomography (microCT) technique, performable with third-genera- tion synchrotron light sources, has been revolutionary, enabling the observation of internal sam- ple details with unprecedented definition, high resolution up to 0.2 mm and allowing the calcu- lation of different morphometric parameters.

We performed microCT experiments on paraffin embedded leiomyoma and myometrial biopsy at the Italian Synchrotron Facility, ELETTRA (Basovizza-TS), using phase-contrast set- tings optimized for non-mineralized biological tissues. For each biopsy, several subvolumes were analyzed: each of them was a 3D portion fully included in the sample bulk and the com- plete set of them allowed to achieve the whole retrieved sample mapping. The quantitative analysis was based on the structural indices usually measured for bone samples: Collagen-Fib- ers-specific-volume, Collagen-Fibers-specific-surface, Mean Collagen Fiber thickness, Mean Col- lagen Fiber number and Mean Collagen Fiber spacing. Furthermore, as Collagen Fibers could vary their orientation depending on the pathology, we also extracted information about the anisotropy of the collagen structure, i.e. the presence of preferential orientation. The anisotropy degree index measures the similarity of a fabric to a uniform distribution and varies between 0 (all observation confined to a single plane or axis) and 1 (perfect isotropy). Finally, the mor- phometric analysis was also applied in order to derive a descriptor for the interconnectivity between the structures.

This preliminary investigation opened new methodologic possibilities for future studies to evaluate the ECM in soft tissues.

Metrics

Metrics Loading ...